  • Mixing 12 2 and 14 2 house wiring - Home Improvement Stack Exchange
    Can I run 12 2 wiring from a load center to a junction box, then use 14 2 for branch circuits? Never a good idea to do this Maybe if you ran out of the one size of wire Why are you wanting to do this to begin with? The only reason I would consider this is to minimize voltage drop for a long run on a lighting-only circuit
  • Combining 12 2 and 14 2 - Mike Holts Forum
    We picked up a 12 2 20 amp homerun and branched off for new outlets (15 amp) for rough in with 14 2 Never been a problem before At one time long ago, it was allowed for switch legs only You can change the breaker to 15 amps though, and be back legal (Unless it feeds an area that requires 20 amp) Inspector was on his game, and correct H
  • Tapping off of 12-2 with 14-2 - Electrician Talk
    I will be getting power from an outlet which i'm sure will be fed with 12-2 I will be using roughly 40 feet of wire and i want to use 14-2 to save money and it's easier to work with
  • Mixing 14 2 and 12 2 wire on one circuit? - DIY Home Improvement Forum
    I have two other outlets that are already wired with 14 2 wire I would like to put the outlets on the same circuit and wondering if it is okay to mix the 14 2 and 12 2 wires on the same circuit IF I swap out the breaker to a 15 AMP
  • Adding 14 2 wire to 12 2 wire - DoItYourself. com
    To directly answer, yes you can mix the wire gauges as long as you have a 15A breaker It's also a very good idea to put a note on the circuit in the panel so that the breaker is not accidentally increased in the future by someone who doesn't know about the #14
  • Can I branch off a 12-2 wire into 14-2 for led recessed lights? - Reddit
    Yes As long as your 12 2 is landed in a 15 amp breaker your fine This not usually done in a residential setting and in your case doesn't seem necessary This is commonly dome for long runs to try and overcome voltage drop
  • Can I connect 14 2 gauge wire to 12 gauge wire in this case?
    I have 12 gauge wires on a 20 amp breaker, and there are 3 power outlets in this circuit Can I create an extended outlet (just for a WIFI router about 50w) using 14 2 gauge wire on that 12 gauge circuit?
  • 14-2 and 12-2 wire on 20 amp circuit code clarification - Houzz
    In previous posts by other users it was determined that 14-2 wire should not be used on a 20 amp circuit My home has a garage outlet that is fed by 12-2 wire, however, the 12-2 line to the outlet enters a junction box where 14-2 wire
  • 14 2 and 12 2 together???? | DIY Home Improvement Forum
    It's fine as long as the 12 2 in question doesn't come from an outlet where 20 amps is needed If it runs straight from the panel to the switch, you're good someone won't be tempted to put that 12 on a 20a breaker I wouls finish with #12, but you can do it if you replace the breaker with a 15a
  • Wiring a 15amp circuit with 12 2 to outlets and 14 2 and 14 3 to lights.
    I'm putting together an electrical plan so I can apply for a building permit to remodel my house and have a question on wire sizes I was told that it would be ok, on a 15 amp circuit to run 12 2 to the receptacles and then run 14 2 and or 14 3 to a switched light