  • Tektronix TDS544A need help deciphering console printout
    Re: Tektronix TDS544A need help deciphering console printout by radioguy123 » January 6th, 2022, 3:12 am Hi Strick Thanks for your post Yes I've probably triple washed this board in soap and water with a toothbrush Before and after changing out all the leaky capacitors I did an unpowered probing of all the power connections
  • Generating a random pattern on AFG3021B - Tektronix and Keithley
    Hello I have been trying to generate an arbitrary square wave on my AFG3021B using ArbExpress My problem is that I want the pattern to be random I noticed that in the software there's the option to use markers 1 and 2 that allow the generation of random pattern How can I get that random pattern from the markers to be applied to my generated square wave and then passed to the AFG3021B
  • DPO3032 - Offset Issue - Tektronix and Keithley
    If I switch from a generic probe (non-Tektronix) to a P6139A probe the offset goes away If there are no probes connected the offset is still there but only in the 1M-ohm setting The Offset is present in both DC and AC coupling (with non-Tektronix probe and no probe) Is there a probe impedence requirement for this scope?
  • New RSA603A gives faulty EVM measurements - Tektronix and Keithley
    Tektronix Real Time Signal Analyzer SignalVu-PC V3 13 0072 Installed Options: Essentials (SignalVu-PC SVE) General Purpose Modulation Analysis (SignalVu-PC SVM) Installed Licenses: [RSA603A – B020990] SVMNL-SVPC: License; General Purpose Modulation Analysis to work with analyzer of acquisition bandwidth less than or equal to 40MHz and MDO
  • Looking for a used Scope - Tektronix and Keithley
    With Tektronix digital scopes you must make sure that every channel has its own digitizer On some 4 channel models the digitizers are shared between two channels (even Tektronix can make a mistake) For digital scopes this is a big no-no
  • TLS216 REPAIR - Tektronix and Keithley
    After one year of inactivity I found that the Acquisition Board and the RS-232 Option Board, are affected by the infamous Leaky Capacitor problem and the unit doesn't pass the SPC test anymore
  • Tektronix and Keithley - Index page
    Who is online In total there are 55 users online :: 2 registered, 0 hidden and 53 guests (based on users active over the past 5 minutes) Most users ever online was 1285 on October 30th, 2018, 11:15 am
  • tek VISA source code - Tektronix and Keithley
    The TekVisa core source-code is internal only and not released unfortunately Is there a specific use-case you had in mind? Tektronix Software Engineer 2 posts • Page 1 of 1 Return to “Other or Discontinued Oscilloscopes” Jump to
  • 466 AC Voltage Displayed On Screen Is Too High - Tektronix and Keithley
    I have a Tek model 466 oscilloscope It accurately measures DC voltage and frequency on both channels AC voltages on both channels, however, are displayed too high (about double the actual voltage) When using both channels to measure the same AC voltage source, both channels show the same voltage display Switching form AC to DC also shows the same voltage on the display screen Gain
  • Delayed Sweep on TDS2024C - Tektronix and Keithley
    Questions in this forum area are community supported Tektronix does not regularly monitor posts in this area 2 posts • Page 1 of 1 MJSTOCKY Posts: 2 Joined: October 10th, 2014, 10:16 am