  • Chapter 10 Means of Egress - ICC Digital Codes
    Exterior walls separating the exterior area of assisted rescue from the interior of the building shall have a minimum fire-resistance rating of 1 hour, rated for exposure to fire from the inside
  • 8. Evacuation facilities - Accessibility Standards Canada
    within an exit stair shaft, provided it is outside the egress width required by the applicable Building Code so that direct access is provided to: an exit, or a fire fighter elevator required by the applicable Building Code; or within a fire compartment that is separated from the remainder of the floor area by a fire separation having a fire-resistance rating not less than that required by the
  • U. S. ACCESS BOARD TECHNICAL GUIDE Accessible Means of Egress
    One hour min fire-rated separation within 10’ (horizontal and vertical) of the exterior area of assisted rescue (3 4 hour rating for opening protectives within this area)
  • Fire Service Access Elevators Coordinate with Accessible Means of Egress
    elevator The FSAE has to be identified by a fire hat symbol (3007 7 5) The SAE is required to have a capacity not less than 3,500 pounds (403 6 1) The FSAE also can be the eleva-tor sized to accommodate the ambulance stretch or elevator machine room; or when the fire depart-ment initiates recall FSAEs must go in
  • ACCESSIBLE MEANS OF EGRESS - iccsafe. org
    The wall between interior and the exterior area of refuge is required to be fire-resistance rated for a minimum of 1 hour to protect persons waiting in this area
  • Accessible Means of Egress - NFPA
    Accessible means of egress in single-story buildings tend to be easier to provide A door with a path to the public way could be considered an accessible means of egress If there are elevation changes, providing ramps instead of, or in addition to, stairs ensures the path remains accessible
  • Elevator machine room rating - The Building Code Forum
    There are two exceptions to this requirement The first allows the reduction of the fire-resistance-rated enclosure to 1 hour where the machine room or space does not abut the hoistway In other words, the machine room or space is in a location where no connection is made with the hoistway
  • Elevator Hoistway Protection Requirements - Code Red Consultants
    A 1- or 2-hour fire resistance rating is required which is dependent on the number of floors connected by the shaft (1-hour if less than 4-stories; 2-hour if 4-stories or more), and the fire resistance rating of the floor assemblies within the building
  • Chapter 30 Elevators and Conveying Systems
    The fire service access elevator lobby shall be enclosed with a smoke barrier having a fire-resistance rating of not less than 1 hour, except that lobby doorways shall comply with Section 3007 6 3
  • SECTION 1007 ACCESSIBLE MEANS OF EGRESS - Corada
    Where walls or openings are between the area for assisted rescue and the interior of the building, the building exterior walls within 10 feet (3048 mm) horizontally of a nonrated wall or unprotected opening shall be constructed as required for a minimum 1-hour fire-resistance rating with 3 4-hour opening protectives